top of page

FINAL DRAWINGS

DETAILS 1:20

DETAIL SECTIONS

The following image shows where from Section 3 the structural details have been taken

Please refer to SECTIONS page to see the original section 3

DETAIL 1

1- metal parapet fixed with metal clips
2- sealing layer, single ply membrane
3- rigid insulation 50mm
4- thermal insulation 125mm
5- reinforced concrete deck 150mm
6- facade post, glass fin
7- double glazing: laminated safety glass
8- gravel
9- slate external flooring 30mm, gravel
10- concrete 170mm
11- soil
12- french dranage
13- concrete screed with underfloor heating pipes 60mm, insulation 140mm, reinforced concrete 200mm/raft foundation/, hardcore

/click to see the full scale drawing/

A2_1:20

DETAIL 2

1- sealing layer, single ply membrane, rigid insulation 50mm, thermal insulation 125mm, reinforced concrete deck 150mm 
2- metal parapet fixed with metal clips
3- vertical timber cladding 30mm boards
4- ventilated cavity between 40mm x 30mm timber battens
5- counterbattens 20mm
6- breathable membrane
7- mineral-fiber thermal insulation 80mm

8- vapour control layer
9- reinforced concrete 200mm
10- parquet 20mm
11- screed 60mm
12- separating layer
13- insulation 70mm
14- reinforced concrete deck 200mm
15- suspended ceiling
16- textured concrete 95mm
17- insulation 80mm

18- vapour control layer
19- reinforced concrete 200mm
20- concrete screed with underfloor heating pipes 60mm, insulation 140mm, reinforced concrete 200mm/raft foundation/, hardcore
21- french drainage
22- soil/earth
23- concrete 170mm
24- slate external flooring 30mm, gravel
25- gravel

​
 

/click to see the full scale drawing/

A2_1:20